10 Operation and use
100_0202_op_0020.fm 27
10.3 Commissioning
1. Firmly hold the machine by the control handle.
2. Check that the starter lever is in the OFF position.
3. Press the starter button on the rechargeable battery.
4. Pay attention to the light progress bar. The LEDs illuminate alternating and then show the current
charge situation of rechargeable battery.
5. With one hand, pull the safety lever and slowly push the starter lever forward.
6. The machine will start and the vibration starts in the forward direction.
Item Designation Item Designation
1 Start button on/off 2 LED light progress bar
NOTICE
If not started, the rechargeable battery automatically switches off after 30 seconds.
Item Designation Item Designation
1 Safety lever 2 Starter lever