CRT 48 Maintenance
5.13 Servicing the Air Cleaner
1. Unlock clamps (a) and remove cover (b).
2. Remove cartridge (c) from air cleaner body.
The filter can be cleaned by blowing compressed air breadthways outside and
inside the cartridge, at a pressure not greater than 4.9 bar (70 psi), or by knocking
the front of the filter several times against a flat surface. Replace filter if it appears
heavily soiled or damaged.
3. Carefully clean out air cleaner cover.
4. Install filter in body.
5. Install cover and lock clamps.
NOTICE: NEVER run engine without air cleaner. Severe engine damage will occur.
WARNING
NEVER use gasoline or other types of low flash point solvents for cleaning the air
cleaner. A fire or explosion could result.