8 Use and operation DPU 130Le
51
Operator's manual
Checking the machine
Check the following points before beginning work:
Machine is undamaged.
Receiver units are free of dirt.
No objects under protective hoods (gloves, tools, etc.).
Fuel level, see chapter Maintenance.
Engine oil level, see chapter Maintenance.
Coolant level, see chapter Maintenance.
Removing the remote control from the holder
1. Unscrew coiled helix cable from remote control.
2. Place coiled helix cable in holder.
3. Screw the sealing cap onto the remote control shorting plug.
4. Remove the remote control from the holder.
Item Designation Item Designation
1 Remote control 4 Coiled helix cable holder
2 Remote control holder 5 Shorting plug with sealing cap
3 Coiled helix cable
NOTICE
Improper handling can cause damage to the coiled helix cable.
f Place coiled helix cable in holder so that it will not be pinched when the
protective hood is closed.