EasyManua.ls Logo

Wacker Neuson DPU130Le

Wacker Neuson DPU130Le
108 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
9 Maintenance
100_0202_mt_0004.fm
74
9.1.3 Regular maintenance
Maintenance work Every
125 hours
Every
250 hours
Every
500 hours
Check the functionality of the
proximity recognition sensor.
Check the function of the
emergency stop switch.
Check hydraulic oil level,
have hydraulic oil topped up if
necessary.
Have hydraulic hoses
checked for damage or leaks
have them changed if nec-
essary. *
Check the base plate vibra-
tion dampers for damage –
have them changed, if neces-
sary. *
Have the fastening screws
checked for tightness: *
Division bar.
Central suspension.
Hydraulic oil tank
Base plate vibration damp-
ers.
Check exciter oil level – fill if
necessary.
Lubricate the protective hood
locks.
Check central suspension for
signs of damage.
Change drive motor engine
oil and oil filter.
Have the fuel filter replaced. *
Change air cleaner cartridge
if the Air cleaner control
lamp is lit, even before the
scheduled time.

Table of Contents

Related product manuals