9 Maintenance
75
100_0202_mt_0004.fm
Regular maintenance
Check the fan's V-belt tension
– if necessary, add tension to
the V-belt. *
Have engine cooling system
hoses and clamps checked. *
Have air induction system
hoses and clamps checked. *
Have exciter oil changed. *
Check the radiator antifreeze.
Have hydraulic oil filter with
breather filter changed. *
Have drive engine valve
clearance checked – have
them adjusted, if necessary. *
* Have these tasks carried out by the service department of your Wacker
Neuson contact person.
Maintenance work Every
1000 hours
or every
2years
Every
4000 hours
or every
4years
Every
6years
Have hydraulic oil changed. *
Have coolant changed. *
Have drive motor drivebelt
changed. *
Have all hydraulic hoses re-
placed. *
* Have these tasks carried out by the service department of your Wacker
Neuson contact person.
Maintenance work Every
125 hours
Every
250 hours
Every
500 hours