8 Use and operation DPU 130Le
69
Operator's manual
Coordinating the transmission channel between the remote control and the machine
1. Turn on remote control.
2. Activate machine.
3. Remove the coiled helix cable from the holder.
4. Unscrew the sealing cap from the remote control shorting plug.
5. Connect the coiled helix cable to the remote control shorting plug and screw
it on.
6. Aim the remote control directly at the front receiver unit.
The display screen shows IR transfer, Address comp.
If the receiver units flash yellow and the display screen shows the hours of
operation, the coordination of the transmission channel has been completed.
7. Unscrew coiled helix cable from remote control.
8. Place coiled helix cable in holder.
9. Screw the sealing cap onto the remote control shorting plug.
Item Designation Item Designation
1 Coiled helix cable 3 Remote control
2 Receiver unit front 4
NOTICE
Improper handling can cause damage to the coiled helix cable.
f When using the coiled helix cable, take care that it is not pinched when
closing the protective hood.