10 Troubleshooting DPU 130Le
99
Operator's manual
Connecting jumper cable
1. Clamp the clamping pliers of the red booster cable to the positive terminal of
the discharged battery.
2. Clamp the second clamping pliers of the red booster cable to the positive
terminal of the donor battery.
3. Clamp the clamping pliers of the black booster cable to the negative terminal
of the donor battery.
4. Clamp the second clamping pliers of the black booster cable to the grounding
of the machine.
Jumpstart
1. Turn on remote control.
2. Activate machine.
3. Briefly hold the start button on the remote control until the engine starts.
If the motor does not start, contact your Wacker Neuson representative.
4. Let the engine run for a few minutes.
Disconnecting booster cable
1. Disconnect the second clamping pliers of the black booster cable from the
grounding of the machine.
2. Disconnect the second clamping pliers of the black booster cable from the
donor battery.
3. Disconnect the clamping pliers of the red booster cable from the positive
terminal of the discharged battery.
4. Disconnect the second clamping pliers of the red booster cable from positive
terminal of the donor battery.
Fastening positive terminal cover
1. Fasten positive terminal cover.
2. Lower battery cover.