Operating manual Piston pump IceBreaker 40-200 ccm (Finishing)
3 Identification
12 Order number 2333538 | Edition 03/2021
Ignition temperature of the coating product
4 Ensure that the ignition temperature of the surrounding gases (pumping product,
cleaning agents) is higher than the maximum permitted surface temperature of the
device.
Ambient temperature
The permissible ambient temperature range is: 5 °C to 50 °C; 41 °F to 122 °F.
Medium supporting atomizing
4 To atomize the product, use only weakly oxidizing gases, e.g., air.
Electrostatic surface spraying
4 Do not spray device parts using electrostatic equipment.
Cleaning
If there are deposits on the surfaces, the device may form electrostatic charges. Flames or
sparks can form during discharge.
4 Remove deposits from the surfaces to maintain conductivity.
4 Use only a damp cloth to clean the device.
Air in the pump fluid
Ignitable gas mixtures can form if air enters the pump fluid.
4 Prevent the pump from taking in air and running dry.
4 If air has been taken in, fix the leak. Then, fill slowly and in a controlled manner until the
air has escaped.
Air in the pumped fluid can be caused by damaged packings.
4 Avoid operating the pump with damaged packing.
4 Ensure that the separating agent tank is filled with sufficient separating agent.
4 Periodically check that the pump is working smoothly, paying special attention to the
presence of air in the pumped fluid.
Filling and emptying
Ignitable gas mixtures can form in the fluid section or product hoses if the pump must be
emptied for maintenance and/or repair purposes.
4 Empty and fill the device slowly and in a controlled manner.
4 Avoid potentially explosive atmosphere in the surroundings.