Operating manual Piston pump IceBreaker 40-200 ccm (Finishing)
3 Identification
Order number 2333538 | Edition 03/2021 11
3 IDENTIFICATION
3.1 EXPLOSION PROTECTION IDENTIFICATION
As defined in Directive 2014/34/EU(ATEX), the device is suitable for use in potentially
explosive areas.
Device type
IceBreaker piston pump
Wildcat 10-70, Wildcat 18-40
Puma 28-40, Puma 21-110
Leopard 35-70, Leopard 35-150, Leopard 48-110, Leopard
26-200
Manufacturer Wagner International AG
9450 Altstätten
Switzerland
II2GExhIIBT3/T4GbX
CE European Communities
Ex Symbol for explosion protection
II Device class II
2 Category 2 (zone 1)
G Ex-atmosphere gas
Ex Ignition protection
h Ignition protection for non-electrical devices
IIB Explosion group
T3 Maximum surface temperature < 200 °C; 392 °F (without drying protec-
tion active)
T4 Maximum surface temperature < 135°C; 275°F (with drying protection
active)
Gb Zone1 high safety level
X Special notices (see chapter Identification "X")
3.2 IDENTIFICATION "X"
The maximum surface temperature corresponds to the permissible product temperature.
This and the permissible ambient temperature can be found in Chapter Technical data.
Safe Handling of WAGNER Spray Devices
Mechanical sparks can form if the device comes into contact with metal.
In an explosive atmosphere:
4 Knocking or pushing metal against metal is to be avoided.
4 Do not drop the device.
Maximum surface temperature
The maximum surface temperature of the piston pump can be reached if it runs dry.
– Ensure that the piston pump is filled with sufficient working or flushing agent.
– Ensure that the separating agent tank is filled with sufficient separating agent.