Operating manual Piston pump IceBreaker 40-200 ccm (Finishing)
4 Basic Safety Instructions
14 Order number 2333538 | Edition 03/2021
4 BASIC SAFETY INSTRUCTIONS
4.1 SAFETY INSTRUCTIONS FOR THE OPERATOR
4 Keep this operating manual at hand near the device at all times.
4 Always follow existing regulations concerning occupational safety and accident
prevention regulations.
4.1.1 Electrical Devices and Equipment
Danger of electric shock!
Danger to life from electric shock:
4 Place and operate device in accordance with the existing safety requirements with
regard to the operating mode and ambient influences.
4 May only be maintained by skilled electricians or under their supervision. With open
housings, the mains voltage poses a danger.
4 Operate device in accordance with the safety regulations and electrotechnical
regulations.
4 Do not disconnect any plug connections during operation.
4 Label plug connections with the warning "Do not disconnect when energized".
4 Must be repaired immediately in the event of problems.
4 Decommission if device poses a danger or is damaged.
4 Must be de-energized before work is commenced.
4 Secure the device against being switched back on without authorization.
4 Inform personnel about planned work.
4 Observe electrical safety regulations.
4 Ground all devices to a common grounding point.
4 Only operate the device with a properly installed socket with a protective ground wire
connection.
4 Keep liquids away from electrical devices.
4.1.2 A Safe Work Environment
Danger due to dangerous fluids or vapors!
Severe or fatal injuries due to explosion danger or inhalation, swallowing or contact with the
skin or eyes.
4 Ensure that the floor in the working area is static dissipative in accordance with
EN61340-4-1 (resistance must not exceed 100 MΩ).
4 Paint mist extraction systems/ventilation systems must be fitted on site according to
local regulations.
4 Make sure that the ground connection and potential equalization of all system parts are
reliable and continuous and can withstand the expected stress (e.g., mechanical stress,
corrosion).
4 Ensure that product hoses/air hoses adapted to the working pressure are used.
4 Ensure that personal protective equipment is available and is used.