5 Description
Order number 2333538 | Edition 03/2021 39
B_03911
2
1
3
4
5
27 MPa
270 bar
3916 psi
1 Fluid section connection 4 Inline filter
2 Relief combination 5 Product output
3 Pressure relief (Relex)
5.8 STROKE COUNT (OPTION)
Each air motor has a 1/8" air connection with which the air pressure in the lower air motor
chamber can be measured. This signal can be used for counting the strokes in an external
controller, for example.
The pressure signal corresponds to the set working air pressure and is available during the
complete upwards stroke of the pump. If both of the signal edges are evaluated, the upper
and lower reversal point can be determined. An air hose (4/2-mm; 0.16/0.08-inch) is used as
an air signal line.
B_03912
1
3
2
Pneumatic pumps: Wildcat, Puma and Leopard
B_03703
4
Pos Order no. Designation
1 9998675 Threaded plug
2 9999066 Male stud elbow
3 9982072 Air hose (per meter)
4 9943049 Pneumatic pre-selection counter
5.9 FEED PUMP (OPTION)
A feed pump can be used with high-viscosity products or longer feed lines.