Operating manual Piston pump IceBreaker 40-200 ccm (Finishing)
5 Description
24 Order number 2333538 | Edition 03/2021
Description Units Wildcat
10-70
Wildcat
10-70 TC
Wildcat
10-70 TC
1.4404
Wildcat
18-40
Ambient temperature - Storage °C
°F
-20 – 60
-4 – 140
Relative humidity % 10–95 (without condensation)
Allowable inclination for operation ∠° ± 10
** For pumps TC 1.4404 with acidic hardeners: Check products for compatibility (chapter
Materials of Paint-wetted Parts for Acidic Hardeners [822]).
* Measured A-rated emission sound pressure level at distance of 1m, LpA1m in accordance
with DINEN14462: 2015. Reference measurements have been made by Suva (Swiss National
Accident Insurance Fund).
WARNING
Exhaust air containing oil!
Risk of poisoning if inhaled.
4 Provide compressed air free from oil and water.
5.5.4 Technical Data for Puma
Description Units Puma 28-40 Puma
21-110
Pump ratio 28:1 21:1
Flow volume per double stroke (DS) cm³ / cc 40 110
Maximum operating pressure MPa
bar
psi
22.4
224
3249
16.8
168
2436
Maximum possible strokes in operation DS/min 60
Maximum recommended strokes per minute in continuous opera-
tion
DS/min 40
Minimum/maximum air inlet pressure MPa
bar
psi
0.25 – 0.8
2.5 – 8
36 – 116
Compressed air quality: free from oil and water Quality standard 7.5.4 according to ISO
8573.1, 2010
7: Particle concentration
5–10mg/m³
5: Humidity: pressure
dew point ≤ 7 °C
4: Oil content ≤5mg/m³
Air inlet diameter (internal thread) inch G1/2"
Minimum diameter of the compressed air supply line mm; inch 9; 0.35
Air consumption at 0.6 MPa; 6 bar; 87 psi per double stroke nl; scf 8.3; 0.29 16.5; 0.58
Air motor piston diameter mm; inch 100; 4