Operating manual Robot powder spray gun PER-X1
5 Description
Order number 2444998 | Edition 10/2022 19
Dimensions:
Polarity Negative / positive (special ac-
cessories)
Pneumatic:
Input air pressure (atomizing air volume) Maximum 3 bar; 0.3 MPa, 43.51
psi
Powder discharge quantity Maximum 450 g/min; maximum
0.99 lbs/min
WARNING
Exhaust air containing oil!
Risk of poisoning if inhaled.
4 Provide compressed air free from oil and water.
Ambient conditions:
If low-melting powders are used, the ambient temperature may have to be lower than 30 °C;
86 °F.
Volume measures for volumes specified in Nm³ (standard cubic meters). One cubic meter of
a gas at 0 °C and 1.013 bar is called norm cubic meter.
Ambient conditions:
Operating temperature range 5–40 °C; 41–104 °F
Relative humidity < 75 %
5.5.2 Dimensions
B
A C
P_04903
Measure-
ment
mm inch
A* 337/349 13.27/13.74
B 231 9.09
C 54 2.13
* With flat jet nozzle/deflector cone