25
TwinControl .
B_02797
1
2
3
4
6
5
B_02796
8
1:2
B_02798
7
OPERATING MANUAL
EDITION 04/2010 PART NO. DOC393831
4.4 FUNCTION
Basic principle:
The paint fl ows continuously and the hardener is metered or injected into the paint in por-
tions in intermittent cycles with a slightly higher pressure.
Description:
The required mixing ratio is entered on the electronic control, and the system can then be
started by pressing the button on the electronic control. This opens material valve A. The
hardener valve B is then opened in pulses, and hardener metered-in according to require-
ment.
4.4.1 DESIGN OF TWINCONTROL BASIC UNITS
1 Pump for A component
2 Solvent pump „S“
3 Pump for B component
4 Control unit TwinControl
6 Stand
7 Mixing unit
8 Trolley
9 Mounting for wall