54
TwinControl .
B
A
SET
TwinControl
B
B
A
A
B_02744
B
A
SET
TwinControl
B
B
A
A
B_02744
B
A
SET
TwinControl
B
B
A
A
B_02744
B
A
SET
TwinControl
B
B
A
A
B_02744
B
A
SET
TwinControl
B
B
A
A
B_02744
OPERATING MANUAL
EDITION 04/2010 PART NO. DOC393831
6.10 BRIEF DESCRIPTION OF THE INDIVIDUAL FUNCTIONS
Basic setting
System is ready to start
„Start“ button-> system starts mixing
System is mixing
Pot life LED fl ashing -> pot life running
Work LED fl ashing -> preload
Work LED illuminated -> system ready to spray
B-valve cycle display -> injection frequency
Display -> see chapter 4.4.5 -> P35.
Automatic stop in case of error
Alarm LED on
Stop LED on
Error code is displayed
Flushing
The fl ushing program runs automatically. B valve to
mixing block, A valve to mixing block, A fl ushing quan-
tity, B fl ushing quantity. Display of quantities and A/B
fl ushing side during fl ushing.
The fl ushing sequence A/B or B/A can be selected (P 40
->see list of service functions, chap. 4.4.5).
6.10.1 BASIC FUNCTIONS FOR THE SPRAYER
If the indication „OFF“ appears after making an entry in
the display, then the input authorisation must be ena-
bled.
Description of the press buttons:
Change numbers. Set -> „+“ (higher) or „-“ (smaller) Terminate data input -> Push button „Stop“
Save numbers -> Set Main menu -> 2 x Push button „Stop“