30
TwinControl .
OPERATING MANUAL
EDITION 04/2010 PART NO. DOC393831
4.4.5 SERVICE FUNCTIONS - OVERVIEW LIST
Software version: B3.30 and C3.30
Item Unit Description
AB cc Mixed material in the hose adjustable
A cc Volume A material from material valve to mixing block adjustable
B cc Volume B material from material valve to mixing block adjustable
SA cc Flushing quantity on A side adjustable
SA will
fl ash
0-200 sec
or cc
Time SA valve (solvent) is open during air - solvent fl ush
2 Flushing quantity on A side
adjustable
SB cc Flushing quantity on B side adjustable
SB will
fl ash
0-200 sec
or cc
Time SB valve (air) is open during air - solvent fl ush
2 Flushing quantity on B side
adjustable
SA + SB
will fl ash
0-200 Number of repetitions during air - solvent fl ush adjustable
Confi guration level 3
P0 0 or 1 Password (0 = no, 1 = yes) for level 1 adjustable
P1 Actual Software version Display
P2 cc Q Control adjustable
P3 cc Value Q Control Display
P4 % Mixing tolerance adjustable
P5 % Actual value mixing tolerance Display
P6 DS/min Protection of dry running pump A adjustable
P7 DS/min Protection of dry running pump B adjustable
P8 DS/min Maxi. number of double strokes pump A where not masked adjustable
P9 DS/min Maxi. number of double strokes pump B where not masked adjustable
P10 0-99999 ml Quantity of material when fl ushing on A side adjustable
P11 0-99999 ml Quantity of material when fl ushing on B side adjustable
P12 min Pot life alarm delay adjustable
P13 % from
stroke
Tolerance limit A reverse point adjustable
P14 ADC Actual value Reverse point stroke sensor A down adjustable
P15 ADC Actual value Reverse point stroke sensor A up adjustable
P16 ADC Actual value Position stroke sensor A Display
P17 % from
stroke
Tolerance limit B reverse point adjustable
P18 ADC Actual value Reverse point stroke sensor B down adjustable
P19 ADC Actual value Reverse point stroke sensor B up adjustable
P20 ADC Actual value Position stroke sensor B Display
P21 0,1,2,3 Unit of measurement (0 = Liter, 1 = US Gallon, 2 = UK Gallon,
3 = conversion factors is adjustable)
adjustable
P22 0 or 1 Gun Flush Box (GFB) (0 = no, 1 = yes) adjustable