P23 0 or 1 Manually leakage check up (0 = no, 1 = yes) adjustable
P24 mm/min Warning tolerance for leakage A adjustable
P25 mm/min Fault tolerance for leakage A adjustable
P26 mm/min Warning tolerance for leakage B adjustable
P27 mm/min Fault tolerance for leakage B adjustable
P28 Liter Total A not resettable Display
P29 Liter Total A not resettable x * 100000 Liter Display
P30 Liter Total B not resettable Display
P31 Liter Total B not resettable x * 100000 Liter Display
P32 Liter Total A fl ush not resettable Display
P33 Liter Total B fl ush not resettable Display
P34 min-1 Turbine frequency in revolutions per min (set value 38000 to 45000) Display
P35 0-6 Front announcement in the mixing process respectable if the gun is
closed:
0 = Mixing ratio (MV);
1 = Flow Rate or Pot life (F_P);
2 = Job sum (JS);
3 = MV and F_P alternating;
4 = MV and JS alternating;
5 = F_P and JS alternating;
6 = MV and F_P and JS alternating)
adjustable
P36 0 or 1 Feed function with pulses of A (0 = off, 1 = on) adjustable
P37 sec 0.0 - 10.0s cycle duration of feed function adjustable
P38 % 0-100% of the cycle duration A valve should be open adjustable
P39 % 0-100% of the feed quantity feed function should be on adjustable
P40 0 or 1 Flushing sequence (0 = AB, 1 = BA) adjustable
P41 0 or 1 Material sequence at fl ush start (0 = AB, 1 = BA) adjustable
P42 0 or 1 Feed sequence (0 = AB, 1 = BA) adjustable
P43 0-9999 Password for level 1 adjustable
P44 0-9999 Password for level 2 adjustable
P45 0-9999 Password for level 3 adjustable
P46 min Time delay for alarm No. 18 (1-10) adjustable
P47 1,2,3 1 = Save customer settings;
2 = Load customer settings
3 = Load factory settings (in stop mode visible only)
adjustable
P48 0,1,2 0 = No calibration in mixing mode
1 = Calibration in mixing mode (A valve will not open)
2 = Calibration in mixing mode (A valve will open)
adjustable
P49 0.1 0 = Flush volume in cc;
1 = fl ush volume in sec
adjustable