39
TwinControl .
OPERATING MANUAL
EDITION 04/2010 PART NO. DOC393831
5.6 ENSURING SUFFICIENT MATERIAL
In the event of hose breakage on the high pressure side or idle running due to lack of ma-
terial, the system switches the pumps off automatically.
WARNING
Fire, explosion and electric shock hazard!
Danger to life from electric shock and explosion
 The unit must be electrically connected to a true earth
ground; the ground in the electrical system is not sufficient.
 A qualified electrician must complete all grounding and wiring
connections and check the resistance.
 Must be operated in accordance with the safety regulations, fire
and electrotechnical regulations.
 Must be de-energized before work is commenced on active
parts.
SIHI_0057_GB
WARNING
Heavy paint mist if earthing is insufficient!
Risk of poisoning
Insufficient paint application quality
Earth all unit components.
Earth the workpieces being painted.
SIHI_0003_GB
5.7 GROUND THE SYSTEM
5.5 FLUID CONNECTIONS
-> Connection of the hose for the cleaning agent (solvent) from the solvent pump via the
suction unit into the container.