32
TwinControl .
OPERATING MANUAL
EDITION 04/2010
PART NO. DOC393831
Software version: B3.30 and C3.30
P50 0-6 Display after stop is pressed:
0 = Mixing ratio (MV);
1 = Pot life only (P);
2 = Job sum (JS);
3 = MV and P alternating;
4 = MV and JS alternating;
5 = P and JS alternating;
6 = MV and P and JS alternating
adjustable
P51 0-999
DS/min
Maximal double stroke fl ush pump A per minute adjustable
P52 0-999
DS/min
Maximal double stroke fl ush pump B per minute adjustable
P53 Cycles Number of A valve cycles resetable Display
P54 Cycles Number of A valve * 100000 cycles resetable Display
P55 Cycles Number of A valve cycles not resetable Display
P56 Cycles Number of A valve * 100000 cycles not resetable Display
P57 Cycles Number of B valve cycles resetable Display
P58 Cycles Number of B valve * 100000 cycles resetable Display
P59 Cycles Number of B valve cycles not resetable Display
P60 Cycles Number of B valve * 100000 cycles not resetable Display
P61 0-99999 Number of A valve * 1000 cycles for service message adjustable
P62 0-99999 Number of B valve * 1000 cycles for service message adjustable
P63 0 or 1 0 = Shot Mode off
1 = Shot Mode on
adjustable
P64 0 or 1 0 = Normal Start
1 = If start is pressed more than 2 sec, fi lling separately A and B will
not be done
adjustable
P65
0 or 1 0 = No fl ushing after error message
1 = Flushing after error message
adjustable
P66
0 or 1 0 = Password for mixing ratio and Shot Mode quantity
1 = No password for mixing ratio and Shot Mode quantity
adjustable
P67
0 or 1 0 = Flow-rate monitoring off
1 = Flow-rate monitoring on
adjustable
P68
0-99999
cc/min
Minimum fl ow rate adjustable
P69
0-99999
cc/min
Maximum fl ow rate adjustable
P70
0.0-20.0 s Delay time until alarm when fl ow is outside limit adjustable