OPERATING MANUAL
EDITION 04/2010 PART NO. DOC393831
1. Switch on air supply 2. Switch on control air
Remark:
For TwinControl with turbine:
control air drives turbine,
electronic is powered by
turbine
3. Turn on main switch
Remark:
Valid only for TwinControl
with cable
Emergency Stop
In the case of unforeseen occurrences
1. Switch off air supply (1)
2. Hold electrically conductive part of the gun against the metal container and trigger
until no further pressure is present.
3. Secure gun
4. Provide collection container and open return valve for A- and B-component and
ushing agent pump. Close all valves again after pressure relief.