7. Relieve pressure of fl ushing agent circuit. Close return ball valve of fl ushing pump and
turn compressed air controller down. Release the gun and trigger, holding the metal
part of the gun against the bucket and pointing it into the earthed bucket, until no
further pressure is present.
8. Secure gun with trigger guard. Close the fl ushing valves by pressing „Stop“.
9. Vent pump A in the same way.
10. Select pump A component „A“. Press „Start“.
11. Close return ball valve of pump A and release the gun, point into the earthed empty
bucket and trigger. When clean solvent emerges, close the gun and secure.
12. Gradually increase pressure in pump A with the pressure controller until maximum
pressure is reached. Maintain the pressure for 3 minutes and check all connection
points of the A-material circuit for leaks.
13. Press „Stop“ on the TwinControl control unit.
14. Relieve pressure of A-material circuit and turn off compressed air controller. Release
the gun and trigger, holding the metal part of the gun against the bucket and pointing
it into the earthed bucket, until no further pressure is present.
15. Secure gun with trigger guard.
16. Select pump B component „B“. Press „Start“.
17. Vent pump B in the same way.
WARNING
Overpressure!
Risk of injury bursting components
 The operating pressure must never exceed the value shown on
the plate.
SIHI_0054_GB
18. Close return ball valve of pump B and release the gun, point into the earthed empty
bucket and trigger. When clean solvent emerges, close the gun and secure.
19. Gradually increase pressure in pump B with the pressure controller until maximum
pressure is reached. Maintain the pressure for 3 minutes and check all connection
points of the B-material circuit for leaks.
20. Press „Stop“ on the TwinControl control unit.
21. Relieve pressure of B-material circuit and turn off compressed air controller. Release
the gun and trigger, holding the metal part of the gun against the bucket and pointing
it into the earthed bucket, until no further pressure is present.
22. Secure gun with trigger guard.