EasyManua.ls Logo

Wareforce DG-E - OPERATING SPECS; OPERATING CYCLES; WASH TANK CAPACITY; WATER TEMPERATURES

Wareforce DG-E
46 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
07610-003-67-17-K
3
OPERATING SPECS
SPECIFICATIONS
Operating Capacity:
Racks per Hour 29
Dishes per Hour 725
Glasses per Hour 1440
Gallons per Rack 1.24
Gallons per Hour 36
Operating Cycles (Seconds):
Wash Time 46
Rinse Time 25
Dwell Time 21
Total Cycle Time 92
Wash Tank Capacity (Gallons): 1.2
Water Temperatures (°F):
Minimum Wash Temperature 120
Minimum Rinse Temperature 120
(140 °F is recommended for both.)
Other Water Requirements:
Water Line Size (NPT) 1.2"
Drain Line Size (NPT) 2"
Flow Pressure (PSI) 20 A 5
Minumum Chlorine Required (PPM): 50
NOTE: Always refer to the machine data plate for specic electrical and water
requirements. The material provided on this page is for reference only and is
subject to change without notice.
OPERATING SPECS
NOTICE
i