PRE-INSTALLATION INSTRUCTIONS FOR DEALERS
The manufacturer has preset the water treatment unit’s sequence of cycles, cycle times, salt dose, exchange capacity and
salt dose refill time.
The dealer should read this page and guide the installer regarding hardness, day override, time of regeneration,
service alarm and buzzer alarm settings before installation.
For the installer, the following must be used:
• Program Installer Settings: Time of Day and Hardness (manufacturer has set system to Immediate Regeneration;
see Operating Displays and Instructions for more details), Service Alarms and Buzzer Alarm (optional displays
only available on the Sanitizer Plus models)
• Read Normal Operating Displays
• Set Time of Day
• Read Power Loss & Error Display
• Be sure system and installation are in compliance with all state and local laws and regulations.
For the homeowner, please read Programming Procedures and Operating Displays and Instructions.
WATER SOFTENERS:
During operation, the normal user display is time of day and gallons per minute.
Flow Rate, Capacity Remaining and Days to a Regeneration are optional displays but are not normally used. Each of
these can be viewed by pressing
NEXT to scroll through them. When stepping through any programming, if no buttons are
pressed within 5 minutes, the display returns to a normal user display. Any changes made prior to the 5 minute time out
are incorporated. To quickly exit any Programming, Installer Settings, etc., press SET CLOCK. Any changes made prior to
the exit are incorporated.