MANUAL REGENERATION
NOTE: For softeners, if brine tank does
not contain salt, fill with salt and wait
at least two hours before regeneration.
If you need to initiate a manual
regeneration immediately, press and
hold REGEN until valve motor starts
(typically 3 seconds).
ERROR
If the display toggles between “Error”
and an error code (i.e. a number), call
a service technician and report the error
code.
BYPASS VALVE OPERATION
To shut off water to the system, position arrow handles as shown in the bypass
operation diagram below. If your valve doesn’t look like the diagram below,
contact your service technician for instructions on how to shut off water.
REGEN TODAY MON
GPM
2:408
PM
REGEN TODAY and TIME OF DAY
will ash alternately if a regeneration
is expected tonight.
ERROR
106
CALL FOR SERVICE
QUICK REFERENCE GUIDE
GENERAL OPERATION
When the system is operating, one of five displays will be shown:
1. Time of day/gpm 4. Days to a regen
2. Flow rate 5. Dealer name and phone number
3. Capacity remaining
Pressing NEXT will toggle between the five choices.
TO SET TIME OF DAY
In the event of a prolonged power outage, time of day flashes,
indicating that this needs to be reset. All other information will be
stored in memory no matter how long the power outage.
1. Accessed by pressing
SET CLOCK
2. Adjust hours with + and buttons, AM/PM toggles at 12
3. Press NEXT
4. Adjust minutes with + and buttons
5. Press NEXT
6. Adjust current day with + and buttons
7. Press NEXT to complete and return to normal operation
DAYS TO A REGEN
GPM
3
A
FLOW RATE
GPM
8.0
TIME OF DAY MON
GPM
2:40A
PM
PHONE NUMBER
DEALER NA
A
CAPACITY REMAINING
GAL
1600
A
CURRENT DAY
SET
MON
TIME MINUTES
SET
TIME HOUR
SET
2:00
AM
2:00
AM
ADJUST HARDNESS, DAYS BETWEEN REGENERATION, TIME
OF REGENERATION AND ALARM BUZZER
For initial set-up or to make adjustments, please complete the following steps.
1. Accessed by pressing NEXT and +
button simultaneously
2. Adjust hardness using + and buttons
3. Press NEXT
4. Adjust days between regenerations
or number of times per day using
+ and buttons
5. Press NEXT
6. Manufacturer has set
regeneration to occur when
zero gallons remain.
7. Press NEXT
8. Turn service alarm by gallons
ON with + and buttons.
Default is OFF.
9. Press NEXT
10. Turn service alarm by time
ON with + and buttons.
Default is OFF.
11. Press NEXT three times
12. Turn alarm buzzer ON
or OFF with + and
buttons.
13. Press NEXT
14. Adjust alarm buzzer start
time with + and buttons.
15. Press NEXT
16. Adjust alarm buzzer end
time with + and buttons.
17. Press NEXT
18. Turn display backlight ON or OFF
with + and buttons. Default is ON.
19. Press NEXT to complete and
return to normal operation.
NORMAL OPERATION BYPASS OPERATION
ALARM BUZZER START
SET
6:00
AM
ALARM BUZZER END
SET
10:00
PM
SERVICE ALARM
SET
OFF
DAYS BETWEEN REGEN
SET
OFF
WATER HARDNESS
SET
20
GR
LIGHT NORMALLY
SET
ON
SERVICE ALARM
SET
OFF
REGEN IMMEDIATE
ON ZERO
GAL
GAL
YR
ALARM BUZZER
SET
ON