32
SANITIZER
®
PLUS TWIN SPECIFICATIONS
*All specs are shown in capacity per tank.
NOTE: Only the -844TW through the -1354TW sizes are approved in the state of Wisconsin.
1
All Sanitizer Plus Twin water conditioners are pre-factory set at medium salting.
NOTE: Influent waters must be at least 3 GPG hardness and 80 TDS. A calcite or corsex unite may be needed for
correct operation.
2
Combined iron and managnese removal varies depending on the form of iron, manganese, pH and other local conditions. On waters
that are pre-chlorinated or where other pre-oxidation occurs, precipitated metal oxides may form that are too fine to be filtered.
3
The pH listed is the minimum for influent water.
4
Optimum pH adjustment occurs at 3.0 gpm or less at maximum salt settings. Higher flow rates will produce less pH adjusted water.
5
Unit not tested for capacity at these flow rates. Water quality may vary.
Twin Series Conditioners
Specifications
Manufactured by Water-Right, Inc. • 1900 Prospect Court • Appleton, WI 54914 • 800-777-1426 • water-right.com
SPE-SAN PL TWIN
RevA0318
CYCLE TIMES AND USAGE
ASP1 SPECIFICATIONS
ASP2 SPECIFICATIONS
MODEL
ASP1-1044TW ASP1-1054TW ASP1-1354TW ASP1-1465TW ASP1-1665TW
1
Capacity:*
(Grains/Lbs. NaCl)
Minimum
7,300 @ 3.2 16,400 @ 6.1 28,300 @ 9.5 40,000 @ 13.0 51,000@ 17.0
Medium
11,400 @ 9.3 20,700 @ 12.4 33,600 @ 15.9 47,000 @ 22.0 60,000 @ 29.0
Maximum
11,800 @ 12.4 22,600 @ 15.9 36,900 @ 21.2 52,000 @ 30.0 51,000 @ 17.0
Amount of Media (Cu.Ft.) 1.0 1.5 2.5 3.5 4.5
Maximum Water Hardness (GPG)
20 30 40 40 40
2
Maximum Iron and Manganese (PPM)
8.0 10.0 15.0 15.0 15.0
3
Minimum pH
6.5 6.0 6.0 6.0 6.0
4
Total pH Adjusted Water
510 510 863 N/A N/A
5
Peak Flow Rate (GPM @ P-PSI)
19.0 @ 8.3 17.0 @ 7.8 19.0 @ 7.6 26.0 @ 25.0 26.0 @ 25.0
Continuous Flow Rate (GPM @ P-PSI)
9.0 @ 2.4 9.0 @ 2.8 9.0 @ 2.7 19.0 @ 15.0 19.0 @ 15.0
Water Pressure Range (PSI)
25-100 25-100 25-100 25-100 25-100
Water Temp. (ºF)
33-100 33-100 33-100 33-100 33-100
Electrical Requirements (volts-hertz) 110-50/60 110-50/60 110-50/60 110-50/60 110-50/60
Pipe Size 1” 1” 1” 1” 1”
Total Dimensions:
Media Tank 10”W x 52”H 10”W x 62”H 13”W x 62”H 14”W x 65”H 16”W x 65”H
Brine Tank 18”W x 33”H 18”W x 33”H 18”W x 40”H 18”W x 40”H 24”W x 41”H
MODEL
ASP2-1044TW ASP2-1054TW ASP2-1354TW ASP2-1465TW ASP2-1665TW
1
Capacity:*
(Grains/Lbs. NaCl)
Minimum
11,100 @ 3.2 22,900 @ 6.1 28,200 @ 9.3 40,000 @ 13.0 52,000 @ 17.0
Medium
19,100 @ 9.3 32,000 @ 12.4 48,300 @ 15.9 68,000 @ 22.0 87,000 @ 29.0
Maximum
20,300 @ 12.4 34,800 @ 15.9 60,300 @ 26.5 84,000 @ 37.0 108,000 @ 48.0
Amount of Media (Cu.Ft.) 1.0 1.5 2.5 3.5 4.5
Maximum Water Hardness (GPG)
40 60 80 80 80
2
Maximum Iron and Manganese (PPM)
8.0 10.0 15.0 15.0 15.0
3
Minimum pH
7.0 7.0 7.0 7.0 7.0
4
Total pH Adjusted Water
N/A N/A N/A N/A N/A
5
Peak Flow Rate (GPM @ P-PSI)
19.0 @ 9.3 17.0 @ 9.1 19.0 @ 8.6 26.0 @ 25.0 26.0 @ 25.0
Continuous Flow Rate (GPM @ P-PSI)
9.0 @ 3.0 8.0 @ 3.7 9.0 @ 2.8 19.0 @ 15.0 19.0 @ 15.0
Water Pressure Range (PSI)
25-100 25-100 25-100 25-100 25-100
Water Temp. (ºF)
33-100 33-100 33-100 33-100 33-100
Electrical Requirements (volts-hertz) 110-50/60 110-50/60 110-50/60 110-50/60 110-50/60
Pipe Size 1” 1” 1” 1” 1”
Total Dimensions:
Media Tank 10”W x 52”H 10”W x 62”H 13”W x 62”H 14”W x 65”H 16”W x 65”H
Brine Tank 18”W x 33”H 18”W x 33”H 18”W x 40”H 18”W x 40”H 24”W x 41”H
MODEL
ASP1-1044
ASP2-1044
ASP1-1054
ASP2-1054
ASP1-1354
ASP2-1354
ASP1-1465
ASP2-1465
ASP1-1665
ASP2-1665
MIN. GAL. MIN. GAL. MIN. GAL. MIN. GAL. MIN. GAL.
Brine Refill
5:51 3 9:53 5 11:53 6 23:00 11.5 30:00 15
Backwash
12 42 12 48 12 90 12 36 12 108
Brine & Rinse
72 29 90 36 90 50 90 72 90 90
Rapid Rinse
4 14 4 16 4 30 4 30 4 36
Total 94 88 116 105 118 176 129 203.5 136 249