STEP 4 – IMMEDIATE REGENERATION: The manufacturer has set the
regeneration to occur when zero gallons remain. When this occurs,
the standby tank will switch into service and provide treated water
while the tank requiring regeneration will start this process.
STEP 5 – SERVICE ALARM GALLONS (optional setting only available on
Conditioner models): The manufacturer has factory set “OFF” as the
default. This feature is used to signal service into the future. This is
typically set by the installing dealer to warn homeowner that service is
required after a preset number of gallons have been consumed. If the
feature is active, a specific gallon amount will appear.
STEP 6 – SERVICE ALARM TIME (optional setting only available on Conditioner
models): The manufacturer has factory set “OFF” as the default. This
feature is used to signal service into the future. This is typically set by
the installing dealer to warn homeowner that service is required after a
period of time has passed. If the feature is active, a specific number of
days will appear.
STEP 7 – ALARM BUZZER (optional setting only available on Conditioner
models): The manufacturer has factory set “ON” as the default. An alarm
will sound (at the indicated time) after a regeneration, if there is no salt
or if another error has occurred. Turn the alarm “OFF” or “ON” using
the + or — buttons. Press
NEXT.
NOTE: This feature allows you to program the time in which the alarm
buzzer will sound, permitting the installer to pick a time when the owner
will be home or awake to hear it.
Setting Alarm Buzzer Start Time: Press + or — button to select the
correct hour the buzzer is to start sounding. Be sure to also set AM or PM
as necessary. (Default is set to 6:00 a.m.) Press
NEXT.
Setting Alarm Buzzer End Time: Press + or — button to select the
correct hour the buzzer is to stop sounding in the day. Be sure to also
set AM or PM as necessary. (Default is set to 10:00 p.m.) Press
NEXT.
STEP 8 – DISPLAY BACKLIGHT: The manufacturer has factory set “ON” by
default. Turn the light “OFF” or “ON” using the + or — buttons.
“OFF” will turn display backlight off after five minutes of keypad
inactivity. Press
NEXT to exit installer programming.
REGEN IMMEDIATE
ON ZERO
GAL
4
5
SERVICE ALARM GAL
SET
100
GAL
SERVICE ALARM
SET
OFF
GAL
ALARM BUZZER START
SET
ALARM BUZZER END
SET
6:00
AM
10:00
PM
ALARM BUZZER
SET
ON
7
LIGHT NORMALLY
SET
ON
8
6
SERVICE ALARM TIME
SET
1.25
YR
SERVICE ALARM
SET
OFF
YR
PROGRAMMING PROCEDURES
NOTE: STEPS 5-7 ARE ONLY AVAILABLE ON CONDITIONER UNITS.
NOTE: To alternate between tanks without activating a regeneration, press and
hold CLOCK and + simultaneously for three seconds.