14.8 Auto-restart
This pump offers an auto-restart feature. When active on power loss, it will restore
the pump when power returns to the operating state it was in when power was lost.
It does not operate when powering down in the middle of a dose; when the pump is
restarted, it will await a press on the START key to begin the interrupted dose
again. Auto-restart is retained while the pump is switched off. When the pump starts
running look for the ! symbol on the display. This ! symbol indicates that the pump
is set for auto-restart.
Do not use auto-restart for more than 100 starts per
hour. We recommend remote control where a high num-
ber of starts is required.
To turn the auto-restart facility on:
Turn off the mains power switch at the rear of the pump.
Depress the START key while switching on the mains power switch at the rear
of the pump.
To turn the auto-restart facility off:
Turn off the mains power switch at the rear of the pump.
Depress the STOP key while switching on the mains power switch at the rear
of the pump.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Watson Marlow Pumps 720DuN and is the answer not in the manual?

Watson Marlow Pumps 720DuN Specifications

General IconGeneral
BrandWatson Marlow Pumps
Model720DuN
CategoryWater Pump
LanguageEnglish

Related product manuals