Thermo Top Evo 5 Troubleshooting
509
62 98 Customer specific fault 3 No additional information
available
In case of frequent occurrence
(> 3):
1) Troubleshooting in air
intake or in exhaust system
(see Section 5.7, Fig. 504,
Point 12)
2) Conduct troubleshooting
in fuel system (see
Section 5.7, Fig. 504,
Point 10)
3) Conduct check of meter-
ing pump (see Section 5.7,
Fig. 504, Point 5)
4) Conduct electrical test of
glow plug (see Section 5.7,
Fig. 504, Point 6)
81 129 EOL checksum error Checksum of EOL dataset is
wrong
Delete fault, fault release/carry
out heater lock-out on heater
(see Section 5.1.1), restart
heater
82 130 No start during testrun No start during testrun This fault can only occur dur-
ing initial start up of the
heater (at vehicle manufac-
turer's plant):
1) Troubleshooting in air
intake or in exhaust system
(see Section 5.7, Fig. 504,
Point 12)
2) Conduct troubleshooting
in fuel system (see
Section 5.7, Fig. 504,
Point 10)
3) Conduct check of meter-
ing pump (see Section 5.7,
Fig. 504, Point 5)
4) Conduct electrical test of
glow plug (see Section 5.7,
Fig. 504, Point 6)
Fault
code
(HEX)
Fault
code
(DEZ)
WTT* fault message Fault details with double-
click in WTT*
Recommended workshop
action
Fig. 502 Overview of general faults entered in fault memory