WWW.WEBER.COM
21
SEAR STATION IGNITION & USAGE
SEAR STATION BURNER IGNITION
m DANGER
Failure to open the lid while igniting the grill’s burners, or not
waiting five minutes to allow the gas to clear if the grill does
not light, may result in an explosive flare-up, which can cause
serious bodily injury or death.
The SEAR STATION burner has an ON or OFF control setting. To ignite the SEAR STATION
burner you must first ignite the two adjacent main burners.
Adjacent Main Burner Snap Ignition
NOTE: Each main burner control knob snap igniter creates a spark from the igniter electrode
to the burner lighting tube. You generate the energy for the spark by pushing in the control
knob and turning to START/HI. This will ignite each individual burner.
m WARNING: Always check hose before using grill for nicks,
cracking, abrasions or cuts. If the hose is found to be damaged
in any way, do not use the grill. Replace using only WEBER
authorised replacement hose. Contact the Customer Service
Representative in your area using the contact information on our
web site.
Log onto www.weber.com.
A) Open the lid (1).
B) Make sure all burner control knobs are turned o (2). (Push control knob in and turn
clockwise to ensure that it is in the OFF position.)
C) Turn on the cylinder valve using one of the appropriate options based on your cylinder
and regulator type (3).
m WARNING: Do not lean over the open grill.
D) Ignite each adjacent SEAR STATION main burner (4). Push the control knob in and turn
to START/HI until you hear the igniter snap - continue to hold control knob in for two
seconds. This action will spark the igniter, the burner lighting tube and then the main
burner.
E) Check that the burner is lit by looking through the cooking grates (5). You should see a
flame. If burner does not light on first try, push control knob in and turn to OFF. Repeat
lighting procedure a second time.
SEAR STATION Burner Lighting: Ignition by an adjacent ignited main burner
F) Turn SEAR STATION burner control knob to the ON position (6).
G) Verify burner ignition by visual inspection of a flame (7).
m WARNING: If ignition does not occur within five seconds, turn
burner control OFF, wait five minutes, and repeat steps F &
G, or refer to “SEAR STATION BURNER MANUAL IGNITION”
instructions.
m WARNING: If the burner still does not light, turn the burner
control knob to OFF and wait five minutes to let the gas clear
before you try again or try to light with a match.
Note: Refer to “MAINTENANCE” for burner removal and cleaning
procedure.
◆
TO EXTINGUISH
Push in and turn each burner control knob clockwise to OFF position. Turn gas supply o
at the source.
◆
OFF ON
The grills illustrated in this
Owner’s Guide may vary slightly
from the model purchased.