EasyManua.ls Logo

Weinmann MEDUMAT Standard - Alternative ventilation procedures

Default Icon
68 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
32 Using the ventilator
EN
5.11 Alternative ventilation procedures
If MEDUMAT Standard ceases to function during a
ventilation procedure, the following alternatives can
be applied:
Ventilation bags
1. Remove the patient valve from the tube or the
mask.
2. Replace it with the ventilation bag, e.g. a WEIN-
MANN Emergency COMBIBAG WM 11000, and
perform manual ventilation.
Exhaustion of oxygen supply
In emergency situations when the oxygen supply
runs out, MEDUMAT Standard can also function
with compressed air.

Table of Contents