WEISS TM15 - External Braking Resistor (Option); Technical Data

Default Icon
172 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Manual R06-201624 / 172
ROTARY INDEXING TABLE CONTROLLER EF2...B
COMPONENT DESCRIPTIONS | 3.2 External braking resistor (option)
3.2 External braking resistor (option)
The Power Modules PM240-2 are assigned to fixed values of the braking resistors:
0.37 kW, 1 AC 230 V, 390 ohm, peak power = 1.5 kW
1.50 kW, 3 AC 400 V, 150 ohm, peak power = 2.75 kW
2.20 kW, 3 AC 400 V, 150 ohm, peak power = 2.75 kW
3.00 kW, 3 AC 400 V, 80 ohm, peak power = 4.0 kW
The peak power is limited to a maximum of 12 sec. in an interval of 240 sec., if there is no performance in the remai-
ning period. It may be necessary to test the stopping time.
Fig. 7: Load diagram for braking resistors in blocksize format
ta = 12 s
t = 240 s
3.2.1 Technical data
Refer to the device manual of the manufacturer for further information.
Order number EF2037B
BWD250390K01R0901SI
EF2150B / EF2220B
BWD500150K01R0901SI
EF2300B
BWD600080K01R1002SI
Suitable for power modules of
frame size
FSA FSB
Peak power P
max kW 1.5 2.5 4.0
Resistance Ω 390 150 80
Tolerance (resistance value) % ± 5 at room temperature
Tolerance coefficient TC - 20...100 at 10
-6
/K
Insulation resistance R
ISO MΩ≥ 100 (Umeas = 1.000 VDC)
Inductance L µH 30 ( f = 300 kHz, U
meas = 50 mV)
Capacitance against housing C pF 300 ( f = 300 kHz, U
meas = 50 mV)
cCSAus approvals - Standard CSA-C22.2
cURus approvals - UL 508
Max. operating voltage U
B
V
700 AC taking the intrinsic safety into account
1,000 DC taking the intrinsic safety into account
600 AC UL approval
850 DC UL approval
Isolation voltage U
ISO V 4,000 AC (AC; f = 50 Hz, t = 1 min)
Max. housing temperature °C 250 (free convection)
Storage temperature °C -25...+85
Weight kg 1.2 1.6 2.5

Table of Contents