5 Service information
Back to contents >
Merrychef conneX
®
service and repair manual 62
1. Ensure the cavity is close to ambient temperature.
2. Enter the Service Settings / Tests and select ‘Recommission Test’ from the appliance tests.
The test will check the appliance in the following order;
Door switch operation
Filter switch operation
Microwave circuits
Cooling fan operation
Convection fan operation
Heater circuit
The test will stop at any point a failure is detected.
After a test has successfully passed, when requested select the green check mark to continue. Selecting the red check mark
as a result of a failure will terminate the recommission test sequence.
Note: If the door is opened during the microwave circuit test, the process will stop and record a failure.
3. When all the tests have been successfully performed the display shows the recommission test has passed. Select the
green check mark to confirm.
4. In the event of a recommission test failure, the detail will be recorded in the Error Log. Rectify any error and repeat
the recommission test.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Welbilt MERRYCHEF conneX and is the answer not in the manual?

Welbilt MERRYCHEF conneX Specifications

General IconGeneral
BrandWelbilt
ModelMERRYCHEF conneX
CategoryCommercial Food Equipment
LanguageEnglish

Related product manuals