Dehumidification function
Using the dehumidification function
When using this feature, remove the air exhaust tube, then remove the rubber cap from the
top condensation drain hole and connect the drain tube to it. The tube should be placed in
a location where water can be drained safely. To improve dehumidification efficiency, all
doors and windows in the room should be closed.
Attention. When using the dehumidification function, the fan speed cannot be changed. It
is set to the lowest level by default.
FULL error
When using the air conditioner, the internal condensate tank may fill up if there is no proper
drainage. This is indicated by the FULL LED or error codes E4 and E2 on the control panel
display. To clear this error, remove the rubber cap from the lower condensate drain hole and