PREPARATIONS
FOR,
INITIAL
START-UP
PRESTART
INSPECTION
Before starting
your
generator
set
for
the
first
time
or after a
prolonged
layoff,
check
the
following
items:
Make
certain
the
cooling
water
thru-hull
petcock
is
open.
•,
Check
the
engine
oil
level:
add
oil
to
maintain
the
level
at
the
full
mark
on
the
dipstick.
Check
the
fuel
supply
and
exarriine
the
fuel
filter/separator
bowls
for
contaminant's.
Check
the
DC
electrical
system.
Inspect
wire
connections
and
battery
cable
connections.
Check
load
leads
for
correct
connection
as
specified
in
the
,
wiring
diagrams.
Examine
air
inlet
anµ
outlet
for
air
flow
obstructions.
Be sure
no
other
generator
or
utility
power
is
connected
to
load
lines.
Be
sure that
in
power
systems
with
a
neutral
line
that
the
neutral
is
properly
grounded
(or
ungrounded)
as
the
system
requires,
and
that
the
generator
neutral
is
properly
connected
to
the
load
neutral.
In single
phase
systems
ati
incomplete
or
open
neutral
can
supply
the
wrong
line-to-
neutral
voltage
on
unbalanced
loads.
Visually
examine
the
unit Look
for
loose
or
missing
parts,
disconnected
wires,
unattached
hoses,
and
check
threaded
connections.
Search
for
any
gasoline
leaks.
Check
the
coolant
level
in
bott1
the
plastic
recovery
tank
and
at
the
manifold.
SPIN-ON
OILFILTER',
NOTE:
After
the
initial running
of
the
generator,
the
air
in
the
engine's cooling system will be purged
to
the coolant
recovery
tank.
Open
the air bleed petcock
to
ensure
that
the
cooling system
is
purged
of
air.
After shutdown and
. after the engine has cooled, the coolant from
the
recovery
tank will be drawn into the engine's cooling system
to
replace
the
pflrged
air.
Before subsequent operation
of
the
g~erator,
the
engine's manifold should be topped
off.
and
the
coolant
recovery
tank_m_ay
need
to
be filled
to
the
MAX
level.
A
CAUTION:
When
starting
the
genera.tor,
it
is
recommended
that
all
AC
loads,
especially
large
motors,
be
switched
OFF
until
the
engine
has
come
up
to
speed
and,
in
cold
climates,
starts
to
warm
up.
This
precaution
wfll
prevent
damage
caused
by
u11anticipated
operation
of
the
AC
machinery
and
will
prevent
a
cold
engine
from
stalling.
THERMOSTAT
HOUSING
·.
COOLANT
PRESSURE
CAP
~.
TO
COOLANT
t.·
RECOVERY
TANK
COOLANT
TEMPERATURE
SWITCH
COOLING
WATER
BY-PASS
INSPECT
PERIODICALLY
Engines & Generators
10