Transport and storage en-US
Installation and operating instructions Wilo-Rexa UNI 11
Example: Wilo-Rexa UNI V05/T06-540/P
40 Key for rated voltage
P
Electrical additional equipment:
without = with bare cable end
A = with float switch and plug
P = with plug
4.8 Scope of delivery
▪Pump with 10m cable
▪AC version with:
– Shockproof plug
– Float switch and shockproof plug
▪Three phase version with
– Bare cable end
– Float switch and CEE plug
▪Installation and operating instructions
4.9 Accessories
▪Cable lengths in length increments of 10m up to max.
30m in single-phase version or max. 50m in three-
phase version
▪Guide system
▪Level controls
▪Fixing accessories and chains
▪Switchgears, relays, and plugs
5 Transport and storage
5.1 Delivery
Following receipt of the shipment the shipment must
be immediately checked for defects (damage, com-
pleteness). Any existing defects must be noted on the
freight documentation! Furthermore, the defects must
be reported to the transport company or manufacturer
on the date of receipt. Claims reported after this date
can no longer be invoked.
5.2 Transport
WARNING
Standing under suspended loads!
People must not stand under suspended loads!
There is a risk of (serious) injury due to falling parts.
The load must not be moved over the work areas in
which people are present!
WARNING
Head and foot injuries due to the absence of
protective equipment!
During work there is a risk of (serious) injury. Wear
the following protective equipment:
• Safety shoes
• If lifting equipment is used, a protective helmet
must be worn in addition!
NOTICE
Use only technically flawless lifting equip-
ment!
For lifting, lowering and transporting the pump, use
only technically flawless lifting equipment. Make
sure that the pump does not jam during lifting and
lowering. Do not exceed the maximum permissible
bearing capacity of the lifting equipment!
CAUTION
Wet packaging can rip!
As a result the product can fall to the ground unpro-
tected and be destroyed. Wet packaging must be
lifted carefully and be immediately replaced!
To protect the pump from damage during transport,
only remove the outer packaging at the operation site.
Pack used pumps for shipping in tear-proof plastic
bags of sufficient size so that they are leakproof.
Furthermore, observe the following points:
Fig.2: Attachment point
▪Adhere to national safety regulations.
▪Use legally specified and permitted lifting gear.
▪Select lifting gear according to the present conditions
(weather, attachment point, load etc.).
▪Only attach lifting gear to attachment points. The fixa-
tion must be made with a shackle.