Marine Installation Manual 2022-03 5-10
5 Engine Automation
5.4 Propulsion control systems
X62DF-S2.0
CPP manoeuvring steps
and warm-up times
The recommended manoeuvring steps and warm-up times for engine power in-
crease are shown in Table 5-3. The shipyard needs to include the engine power-
up/down program in the PCS.
Table 5-3 Recommended manoeuvring steps and warm-up times for CPP
Load reduction is possible in half the time of values mentioned in Table 5-3.
Figure 5-7 Full sea load steps in CPP load-up program
Manoeuvring
position
Recommended
CMCR power
[%]
Recommended warm-
up time per load step
[min]
Min. warm-up time
per load step
[min]
DEAD SLOW 1.5 - 4.5 0 0
SLOW 4 - 9 0 0
HALF 9 - 17 0.1 0.1
FULL 22 - 34 0.5 0.5
FULL SEA 1 78 30 23
FULL SEA 2 100 40 30
SM-0539
Warm-up time - CPP
Minimum
Recommended
0
10 3020 40 50 60 70 80
60
70
80
90
100
50
40
30
20
[min]
Minimum warm-up time
CMCR power
[%]
FULL
FULL SEA 1
FULL SEA 2