Marine Installation Manual 2022-03 3-5
3 Engine Installation
3.2 Conditions and requirements
X62DF-S2.0
3.2 Conditions and requirements
3.2.1 Pressure and temperature ranges
Please refer to the document ‘Usual values and safeguard settings’, which is
provided by WinGD under the following link:
Usual values and safeguard settings
For signal processing see also 5.6.1 Signal processing, 5-12.
3.2.2 Operating conditions
The engine can be operated without any restrictions in the ambient condition
range winter’, as permissible by GTD, up to design conditions. Operation out-
side these limits is possible, but further measures might need to be taken and the
power output might be limited (see 4.11.4 Outside ambient air temperature,
4-111). For project-specific support please contact WinGD.
Reference conditions
Engine performance data like BSEC, BSEF, tEaT and others are based on
reference conditions. These conditions are specified in ISO standard 15550 (core
standard) and, for marine application, in ISO standard 3046 (satellite standard)
as follows:
Design conditions
The capacities of ancillaries are specified according to ISO standard 3046-1
(clause 11.4) following the International Association of Classification Societies
(IACS) and are defined as design conditions:
Air temperature before blower:
Engine room ambient air temperature:
Coolant temperature before SAC:
Barometric pressure:
Relative humidity:
25 °C
25 °C
25 °C
1,000mbar
30 %
Air temperature before blower:
Engine room ambient air temperature:
Coolant temperature before SAC:
Barometric pressure:
Relative humidity:
45 °C
45 °C
36 °C
1,000mbar
60 %