Marine Installation Manual 2022-03 6-12
6 Engine Dynamics
6.2 External lateral forces and moments
X62DF-S2.0
Figure 6-11 Engine stays arrangement on the exhaust side
Figure 6-12 Engine stays arrangement on the engine’s fuel side
Recommended
number of stays
No. of
cyl.
SM-0785
Available attachment points on the
platform of the engines exhaust side
12
3
4
5
12
3
4
5
6
12
3
4
5
6
7
12
3
4
5
6
7
8
* Usually no stays
are required for 7 cyl.
8
7
6
Recommended: 4
Optional: -
Recommended: 2*
Optional: +2
Recommended: 2
Optional: +2
Recommended: 2
Optional: +2
5
Recommended
number of stays
No. of
cyl.
SM-0786
Available attachment points on
the platform of the engines fuel side
12
3
4
5
12
3
4
5
6
12
3
4
5
6
7
12
3
4
5
6
7
8
* Usually no stays
are required for 7 cyl.
8
7
6
Recommended: 4
Optional: -
Recommended: 2*
Optional: +2
Recommended: 2
Optional: +2
Recommended: 2
Optional: +2
5