23 / 47
But if you’re using “3. DEFAULT” battery type. We need more information regarding your battery.
1.PYLON
PYLONTECH US2000 PLUS / US2000B
Note: Please confirm with representative of PYLONTECH that your battery
is compatible with WKS i3/i4/i5/i6
2. DARFON DARFON 14S31P ESS
LEAD ACID / LEAD CRYSTAL / AQUION battery
All batteries that comply with WATTUNEED’S BMS CAN communication protocol.
5. Alpha. ESS M48112-P / SMILE-BAT
4)*Set battery capacity (only for DEFAULT battery type)
Press “Up” or “Down” to change the 1
st
digit, press “OK” to switch to next digit. After changing the battery capacity
per your battery specification, press “Ok”, then “Set max charge voltage” will pop up.
5)*Set max charge voltage (only for DEFAULT battery type)
Press “Up” or “Down” to change the 1
st
digit, press “OK” to switch to next digit. After changing max charge voltage
per your battery specification, press “Ok”, then “Set max charge current” will pop up.
6)*Set max charge current (only for DEFAULT battery type)
Press “Up” or “Down” to change the 1
st
digit, press “OK” to switch to next digit. After changing the max charge
current per your battery specification, press “Ok”, then “Set max protect voltage” will pop up.
7)*Set max protect voltage (only for DEFAULT battery type)
Press “Up” or “Down” to change the 1
st
digit, press “OK” to switch to next digit. After changing the max protect
voltage per your battery specification, press “Ok”, then “Set min discharge voltage” will pop up.
8)*Set min discharge voltage (only for DEFAULT battery type)
Press “Up” or “Down” to change the 1
st
digit, press “OK” to switch to next digit. After changing the min discharge
voltage per your battery specification, press “Ok”, then “Set max discharge current” will pop up.
9)*Set max discharge current (only for DEFAULT battery type)
Press “Up” or “Down” to change the 1
st
digit, press “OK” to switch to next digit. After changing the max discharge
current per your battery specification, press “Ok”, then “Set min protect voltage” will pop up.
10)*Set min protect voltage (only for DEFAULT battery type)
Press “Up” or “Down” to change the 1
st
digit, press “OK” to switch to next digit. After changing the min protect
voltage per your battery specification, press “Ok”, then “Set discharge depth” will pop up.