106
UserManualWMFespressoNEXT
Appendix: Technical data
Nominal power rating 6.0–7.0kW
Power supply 380–415V
50/60Hz (3/N/PE)
Illumination LED
Degree of protection IP X0
Protection class Protection class I
Calibration pressure Boiler 0.25MPa (2.5bar)
Continuous sound
pressure level (Lpa)
< 70dB(A)
Ambient temperature +5°C to maximum +35°C
(empty the water system in case of frost).
(3
Maximum humidity 80 % relative humidity without condensation.
Do not use device outdoors.
Installation surface/
water spray
The device must be placed and levelled on
ahorizontal, sturdy, water-resistant, and heatproof
base.
The device must not be cleaned using awater jet.
The device must be installed where it is protected
against water spray. The device must not be located
on asurface that is sprayed or cleaned with awater
hose, steam jet, steam cleaner, or similar devices.
We reserve the right to make technical modifications.
(3
Can be emptied only by WMFService.