UserManualWMFespressoNEXT
Appendix: Technical data
Installation clearances For operating, service, and safety reasons the
machine should be installed with aclearance from
the building or non-WMFcomponents of not less
than 50mm at the sides and 50mm at the rear
side. Aminimum working space of 800mm in front
of the coffee machine is recommended. Clearance
of at least 200mm above the product hopper is
recommended. The height of the installation surface
above the floor is at least 850mm. If the coffee
machine connections are to be run downwards
through the counter, please make space for the
lines, which can reduce the usable space below the
machine.
Installation dimensions of
the water filter
See the User Manual for the water filter.
We reserve the right to make technical modifications.
These specifications for the electrical connection and the standards quoted
apply for connecting the coffee machine in EU countries. It may be necessary
to also observe additional country-specific regulations. Outside the EU
countries acceptance of the standards quoted is to be checked by the legal
entity or natural person who wishes to use the coffee machine.
The customer's on-site electrical system must be designed to meet country-
specific regulations per IEC60364and must match the information on the
ratingplate.
An isolated ground socket or acountry-specific single-phase socket for
single-phase connection, or a5-pole CEE/CEKON socket per DINEN50310
VDE0800–2-310or acountry-specific multi-pole socket for athree-phase
connection, must be available near the machine. The sockets are part of the
customer‘s on-site installation. The power cord must not come into contact with
hot surfaces. If the power cord for this device is damaged then it must be replaced
by our service personnel or asimilarly qualified person, in order to prevent hazards.
In order to avoid possible malfunctions from arising in our shielded data lines
due to potential equalisation currents between the devices, an additional
potential equalisation unit should be planned for devices connected to the
vending system (see DINEN50310 VDE0800–2-310).