13. SMS Receiving Number Setting
Note: You can set a maximum of 3 SMS numbers.
While in settings mode, use the keypad to enter [57] ~ [59], then input the SMS receiving number,
and then press [#] button to confirm. The main unit will make a beep, the [Signal] indicator will
flicker once and you will hear “setting completed”, which indicate setup successfully.
Operating method: [XX][YY…YY][#]
XX indicates: address codes of message-receiving numbers from the
first number to the third number [57] ~ [59]
YY…YY indicates: the SMS receiving number
For example: setup 13822222222 as the first SMS receiving number
Operating method: [57][138222222][#]
14. Delete SMS Receiving Number
While in settings mode, use the keypad to enter [57] ~ [59], and then press [#] button to confirm.
The main unit will make a beep, the [Signal] indicator will flicker once and you will hear “delete
completed”, which indicate SMS number is deleted successfully.
Operating method: [XX][#]
XX indicates: address codes of message-receiving numbers from the
first group to the third group [57] ~ [59]
For example: delete the first SMS user number from the system
Operating method: [57][#]
15. Defence Zone Programming
If you want to change the alarm attributes of the defence zones, such as turn off the siren when
system alarms, you can do it by defence zone programming.
While in settings mode, use the keypad to enter [60], then the defence zone number [01~99], then
input defence zone type [1~4], then input defence zone location number [1~8], and then select siren
on/off [0/1], finally press [#] to confirm. You will hear the main unit emit a long beep and a voice
prompt “setting completed”.
Operating method: [60][AA][B][C][D][#]
AA: defence zone number [01~99] means zone 1 to zone 99;
B: defence zone type
[1]: real-time defence zone – alarm will be triggered immediately when a sensor is triggered
[2]: 40 seconds delay defence zone – alarm will be triggered 40 seconds after a sensor is triggered
[3]: 24 hours defence zone – alarm will be triggered immediately when a sensor is triggered even
when the alarm is not armed. This zone type is used for sensors that need to be on all the time like
smoke sensors etc.
[4]: bypass defence zone – alarm will not be triggered if sensors on this zone is triggered.
C: defence zone location (locations are a way to give the user an idea on what zone were triggered
when the alarm calls or SMS the user).
Page 14 Wolf Secure http://www.wolfsecure-gsmalarms.co.za