3064810_201804 57
27.Drainingtheheatingsystem
Drainingtheheatingsystem:
Switch OFF the condensing boiler at the red ON/OFF switch in the WOLF logo.
Close the gas ball valve.
Allow the temperature in the heating circuit to cool to at least 40 °C.
(Risk of scalding)
Safeguard the heating system against accidental reconnection to the power supply.
Open the drain valve (boiler drain & fill valve, on site).
Open the air vent valves on the radiators.
Drain the heating water.