88 3064810_201804
40.Technicalmaintenanceanddesign
data
NTC
Sensorresistances
Boiler water temperature sensor, cylinder temperature sensor, DHW outlet temperature
sensor,outsidetemperaturesensor,returntemperaturesensor,eHLSCsensor,uegas
temperature sensor, header temperature sensor.
Temp. °C Resist.Ω Temp. °C Resist.Ω Temp. °C Resist.Ω Temp. °C Resist.Ω
-17 40,810 17 7162 51 1733 85 535
-16 38,560 18 6841 52 1669 86 519
-15 36,447 19 6536 53 1608 87 503
-14 34,463 20 6247 54 1549 88 487
-13 32,599 21 5972 55 1493 89 472
-12 30,846 22 5710 56 1438 90 458
-11 29,198 23 5461 57 1387 91 444
-10 27,648 24 5225 58 1337 92 431
-9 26,189 25 5000 59 1289 93 418
-8 24,816 26 4786 60 1244 94 406
-7 23,523 27 4582 61 1200 95 393
-6 22,305 28 4388 62 1158 96 382
-5 21,157 29 4204 63 1117 97 371
-4 20,075 30 4028 64 1078 98 360
-3 19,054 31 3860 65 1041 99 349
-2 18,091 32 3701 66 1005 100 339
-1 17,183 33 3549 67 971 101 330
0 16,325 34 3403 68 938 102 320
1 15,515 35 3265 69 906 103 311
2 14,750 36 3133 70 876 104 302
3 14,027 37 3007 71 846 105 294
4 13,344 38 2887 72 818 106 285
5 12,697 39 2772 73 791 107 277
6 12,086 40 2662 74 765 108 270
7 11,508 41 2558 75 740 109 262
8 10,961 42 2458 76 716 110 255
9 10,442 43 2362 77 693 111 248
10 9952 44 2271 78 670 112 241
11 9487 45 2183 79 649 113 235
12 9046 46 2100 80 628 114 228
13 8629 47 2020 81 608 115 222
14 8233 48 1944 82 589 116 216
15 7857 49 1870 83 570 117 211
16 7501 50 1800 84 552 118 205
Connectiontypes
Type
1)
Operating mode Can be connected to
Openue
Room-
sealed
Chimney,
moisture resistant
Air/uegas
chimney
Balanced
ue
Certied
rm. sealed
balanced
ue
Moisture-
resistantue
B23, B33, C13x,
C33x, C43x, C53,
C53x, C83x, C93x
X X B33, C53, C83x C43x C13x
2)
,
C33x, C53x
C63x B23, C53x,
C83x, C93x
1)
Marking"x"indicatesthatallcomponentsoftheuegasroutearesurroundedbycombustionair.
2)
In Switzerland, observe the G1 gas guidelines.