APPLIANCE INFORMATION
Greenstar Highflow CDi
ErP
- 6720818077 (2016/04)8
2.3 Product data on energy consumption
The following product data satisfies the requirements of the EU Regulations No. 811/2013, No. 812/2013, No. 813/2013 and No. 814/2013
supplementing Directive 2010/30/EU.
Product data Symbol Unit 7731600098 7731600099 7731600100 7731600101
Product type 440CDi
ErP
440CDi
ErP
LPG 550CDi
ErP
550CDi
ErP
LPG
Condensing boiler Yes Yes Yes Yes
Combination heater Yes Yes Yes Yes
Rated heat output P
rated
kW 30 30 31 31
Seasonal space heating energy efficiency η
s
%92 92 92 92
Energy efficiency class A A A A
Useful heat output
At rated heat output and high temperature regime
1)
1) High temperature regime means 60 °C return temperature at heater inlet and 80 °C flow temperature at heater outlet.
P
4
kW 29.6 29.6 31.0 31.0
At 30 % of rated heat output and low temperature regime
2)
2) Low temperature means for condensing boilers 30 °C, for low-temperature boilers 37 °C and for other heaters 50 °C return temperature (at heater inlet).
P
1
kW 9.6 9.6 10.0 10.0
Useful efficiency
At rated heat output and high temperature regime
1)
η
4
% 88.5 88.5 88.5 88.5
At 30 % of rated heat output and low temperature regime
2)
η
1
% 97.1 97.1 97.1 97.1
Auxiliary electricity consumption
At full load el
max
kW 0.041 0.041 0.042 0.042
At part load el
min
kW 0.018 0.018 0.018 0.018
In standby mode P
SB
kW 0.004 0.004 0.004 0.004
Other items
Standby heat loss P
stby
kW 0.053 0.053 0.053 0.053
Emissions of nitrogen oxides NOx mg/kWh 23 23 23 23
Sound power level, indoors L
WA
dB(A) 53 53 52 52
Additional data for combination heaters
Declared load profile XL XL XL XL
Daily electricity consumption Q
elec
kWh 0.350 0.350 0.357 0.357
Annual electricity consumption AEC kWh 77 77 79 79
Daily fuel consumption Q
fuel
kWh 27.356 27.356 28.047 28.047
Annual fuel consumption AFC GJ 1,672 1,672 1,714 1,714
Water heating energy efficiency η
wh
%72 72 71 71
Water heating energy efficiency class B B B B
Table 7 Product data for energy consumption

Table of Contents

Other manuals for Worcester GREENSTAR HIGHFLOW 440CDI ERP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Worcester GREENSTAR HIGHFLOW 440CDI ERP and is the answer not in the manual?

Worcester GREENSTAR HIGHFLOW 440CDI ERP Specifications

General IconGeneral
ModelGreenstar Highflow 440CDi ErP
CategoryBoiler
TypeCombi
ErP RatingA
Hot Water Flow Rate20 l/min
Fuel TypeNatural Gas
Gas TypeNatural Gas
Warranty5 years
MountingWall Mounted