EasyManuals Logo

Xantrex BC3012 User Manual

Xantrex BC3012
62 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #20 background imageLoading...
Page #20 background image
Introduction
1–8 975-0188-01-01
Battery Bank Size Requirements
The BC Series is designed to work with a minimum battery bank size. Each bank
should meet the minimum Ah rating shown in Table 1-1.
Battery Temperature Sensors
Xantrex strongly recommends that you install a Battery Temperature Sensor (BTS)
to protect your battery and improve charging accuracy. It is best to use a separate
BTS with each individual battery bank, to provide optimal charging and protection
of each bank. If no BTS is connected, the charger defaults to the charging
conditions for 40 °C (104 °F). At this temperature the charging voltage is lower to
keep batteries from overcharging; charging will be slower and the batteries will be
slightly undercharged.
One BTS is provided with your BC Series, and additional battery temperature
sensors may be purchased separately.
Table 1-1
Minimum Battery Bank Size
BC 1524 BC 2524 BC 3012 BC 5012
Minimum Battery
Bank Size (Ah)
30 50 60 100
BC_Charger_User.book Page 8 Friday, August 12, 2005 3:31 PM

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Xantrex BC3012 and is the answer not in the manual?

Xantrex BC3012 Specifications

General IconGeneral
BrandXantrex
ModelBC3012
CategoryBattery Charger
LanguageEnglish

Related product manuals