Installation
220 975-0131-01-01
Mounting on Poles or Rails
To mount the unit using poles:
1. Ensure that poles or rails are securely assembled in place. If using horizontal
rails, three rails are required: two for the mounting bracket and a third for
securing the bottom edge of the inverter wiring box (see Figure 2-9).
2. Connect the mounting bracket vertically to the poles or rails (Figure 2-9):
Be sure to use at least two bolts to secure the mounting bracket to the
support.
Position the lower edge of the bracket a minimum of 110 cm (43 inches)
above the floor or ground.
3. If using a single vertical pole, ensure that the inverter is secure and unable to
rotate around the pole.
Figure 2-9
Examples of Mounting on a Pole or Rails
Ground /
Floor
Ground /
Floor
Mounting Bracket
110 cm
(43)
100 cm
(39)
At least 2 bolts to
secure bracket to
poles/rails.
15 cm
(5.9)
48 cm
(18.9)
For securing
the bottom of
the wiring box

Table of Contents