The Administration screen will display parameters in the following tables:
Enter Group No. to define security level
Set the amount of time in minutes before current user is automatically
logged out. A value of zero will disable this feature.
All Primary Screen Buttons are displayed to navigate to those screens
Navigates to ADMIN Basic Screens
Each level of security allows different levels of access to the C410:V3 controller control
functionality please refer to Appendix 2 for details.
Note: Software version numbers shown above may not match the most current software
revision.
Available from the ADMIN screen. It allows the Administrator to reset Pump Cycle count. It
also allows manual control of Flow Control Valve, SOL1; with that controlling flow direction
of pneumatic system. The controller must be in the standby mode.
WARNING:
Do not turn the Sol. Force to the ON position when the XCell
TM
ATF is connected to
the P-box (with air pressure utility). Doing so may over expand the diaphragm
causing potential blowout.