Corrective
Action
10.
Not enough developer material in the
10.
Check the level of the developer material. The material
developer module. should be above the baffle in the rear of the module
and forming v-shaped piles against the rear of the
module. If not enough. replace the developer material
REP
9.9.
1 1.
Damp media. 1 la. Cut sheet media
(Continued)
Make a copy using a sheet of media from the middle of
the stack of media in the Cut Sheet Feeder or the media
storage on the stand.
If the problem
is
corrected, check that the media heater
is
working. Go to one of the following:
1.
Damp Media RAP in Section
8B.
2.
OF1
Media Clea,ter
RAP
in Section
2.
11
b.
Roll media
Remove and discard the first
3
to
6
feet
(1
to
2
metres)
of media from the roll.
Make
a copy on the new media.
If the problem
is
corrected, ensure that the roll media
is
being stored correctly.
12.
Developer material has more than
30K
feet
12.
Replace the developer material (REP
9.8)
and
(9K metres) of copies on
it.
perform the Electrostatic Series (ADJ
9.3).
13.
The copy
is
not fused.
13.
Go to the
CQ
22
Unfused Copy RAP.
14. Airborne chemicals
14.
Some chemicals can cause damage or contamination
of the drum.
Wash (General Procedures) or replace the drum (REP
9.3) and perform the Electrostatic Series (ADJ
9.3).
If
the problem
still
exists, notify technical support.
6/93
CQ
11
The
Light
Copy
(Overall)
3-54
2510/2515