Replacing the Pressure Roll Assembly
Caution
Make sure the press is powered off. Do not perform this replacement procedure with
the power on or electrical power supplied to the press. Allow the fuser to cool down for
50 minutes before performing any maintenance.
1. Perform the steps for Removing the Fuser Module.
2. Perform the steps for Replacing the Stripper Finger Assembly
3. Once the Fuser Belt Assembly is out of the press and the stripper finger bracket
removed, you can access and remove the Pressure Roll Assembly:
a) Push down and release the front and back Bearing Holder Springs, and move each
spring into the holding position.
b) Install the Pressure Roll Handles under the bearings on each side of the roll.
c) Lift the Pressure Roll straight out of the press and place in an available box.
Xerox
®
Versant™ 2100 Press5-26
Quick Start Guide
Maintenance